Operating the wearable
The wearable is operated with a single button and gives feedback through an LED and a buzzer (vibration).
Button actions
- Single press: show status
- Long press (2 s): start calibration
- Long press (5 s): switch off
- Triple press: silent mode on/off
Status LED meanings
- Solid green: connected and calibrated
- Two short green flashes: not calibrated, ready for use
- Blue: corrective vibration (bending or overextending)
- Slow red pulse: silent mode is on
- Breathing green: charging
- Solid green (on the charger): fully charged
- Red flashes: error, see Troubleshooting
Silent mode
A triple press switches between the two modes: Normal ⇄ Silent. In silent mode the buzzer is switched off and the red LED pulses slowly. Triple-press again to turn the feedback back on.
Switching off
Hold the button for about 5 seconds, past the single calibration buzz. Release when you feel fast, repeated buzzing and the red LED flashes.
The wearable also switches itself off after a period of inactivity to save the battery. Press the button, or put it back in the Pro Kit, to switch it on again.
Charging & battery
Charge the wearable with the USB-C cable, or place it in the Pro Kit. While charging, the LED breathes green; once fully charged it stays solid green.
When the battery is almost empty, the wearable buzzes rapidly and flashes red for a few seconds, then switches off.
For users with a beta SpineWise Pro Kit, the wearables only charge if the USB cable AND the charger are plugged in.
Troubleshooting
When the LED flashes red, there may be several causes:
- the wearables are too far apart
- the wearable's battery is empty
- a wearable from another set is being used (e.g. collar 3 and belt 4)